Parameters ASDA-B2-F
7-22
September, 2015
7
P1-xx Basic Parameters
P1-00
▲
Reserved
P1-01
●
CTL
Input Setting of Control Mode and Control
Command
Address: 0102H
0103H
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.1, Table 7.1
Default: 0B
Control
Mode:
ALL
Unit: P (pulse); S (r/min); T (N-M)
Range: 00 ~ 110F
Format: HEX
Data Size: 16-bit
Settings:
DIO setting value
Control mode setting
Direction control of torque output
Not in use
Control Mode Setting
Sz: Speed Control Mode (Zero Speed / Internal Speed Command. It can be slected via DI.SPD0
and DI.SPD1)
Tz: Torque Control Mode (Zero Speed / Internal Speed Command. It can be selected via DI.TCM0
and DI.TCM1)
Torque Output Direction Setting
-
0
1
Forward
Reverse
DIO Setting
0: When switching mode, DIO (P2-10 ~ P2-22) remains its original setting and will not be changed.
1: When switching mode, DIO (P2-10 ~ P2-22)
can be reset to the default value of each
operational mode automatically.
Mode
Sz
Tz
04
▲
05
▲
0B
DMCNET Mode
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...