ASDA-B2-F Parameters
September, 2015
7-45
7
P2-35
PDEV
Condition of Excessive Position Control
Deviation Warning
Address: 0246H
0247H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: 3840000
Control
Mode:
DMCNET
Unit: Pulse
Range: 1 ~ 128000000
Format: DEC
Data Size: 32-bit
Settings:
It is the setting of excessive position control deviation warning in servo drive error display (P0-01).
P2-36~P2-42
Reserved
P2-43
NCF2
Resonance Suppression (Notch Filter) (2)
Address: 0256H
0257H
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.3.6
Default: 1000
Control
Mode:
ALL
Unit: Hz
Range: 50 ~ 2000
Format: DEC
Data Size: 16-bit
Settings:
The second setting value of resonance frequency. If P2-44 is set to 0, this function is disabled.
P2-23 and P2-24 are the first group of notch filter.
P2-44
DPH2
Resonance Suppression (Notch Filter)
Attenuation Rate (2)
Address: 0258H
0259H
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.3.6
Default: 0
Control
Mode:
ALL
Unit: -dB
Range:
0 ~ 32 (0: Disable the function of
notch filter)
Format: DEC
Data Size: 16-bit
Settings:
The second resonance suppression (notch filter) attenuation rate. When this parameter is set to 0,
the function of notch filter is disabled.
Note:
If the value of attenuation rate is set to 5, then, it would be -5 dB.
P2-45
NCF3
Resonance Suppression (Notch Filter) (3)
Address: 025AH
025BH
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.3.6
Default: 1000
Control
Mode:
ALL
Unit: Hz
Range: 50 ~ 2000
Format: DEC
Data Size: 16-bit
Settings:
The third setting value of resonance frequency. If P2-46 is set to 0, this function is disabled. P2-23
and P2-24 are the first group of notch filter.
P2-46
DPH3
Resonance Suppression (Notch Filter)
Attenuation Rate (3)
Address: 025CH
025DH
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.3.6
Default: 0
Control
Mode:
ALL
Unit: -dB
Range: 0 ~ 32
Format: DEC
Data Size: 16-bit
Settings:
The third resonance suppression (notch filter) attenuation rate. When this parameter is set to 0, the
function of notch filter is disabled. If the value of attenuation rate is set to 5, then, it would be -5 dB.
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...