Control Mode of Operation ASDA-B2-F
6-6
September, 2015
6
6.2.4 Low-pass Filter
Relevant Parameters (Please refer to Chapter 7 for detailed description):
Parameter
Abbr.
Function
P1-08
PRLT
Smooth Constant of Position Command (Low-pass Filter)
P1-45
GR2
Gear Ratio (Denominator) (M)
6.2.5 Gain Adjustment of Position Loop
Before setting the position control unit, users have to manually complete the setting of tuning
mode selection (P2-32) since the speed loop is included in position loop. Then, set the position
loop gain (P2-00) and position feed forward gain (P2-02). Users also can use the auto mode to
automatically set the gain of speed and position control unit.
1. Proportional gain: Increase the gain so as to enhance the response bandwidth of position
loop.
2. Feed forward gain: Minimize the deviation of phase delay.
The position loop bandwidth cannot exceed the speed loop bandwidth. It is suggested that:
4
fv
fp
. fv: response bandwidth of speed loop (Hz).
KPP = 2 ×
× fp. fp: response bandwidth of position loop (Hz).
For example: the desired position bandwidth is 20 Hz
KPP = 2 ×
× 20= 125.
Relevant Parameters (Please refer to Chapter 7 for detailed description):
Parameter
Abbr.
Function
P2-00 KPP
Position
Loop
Gain
P2-02
PFG
Position Feed Forward Gain
Target Position
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...