ASDA-B2-F Parameters
September, 2015
7-7
7
Speed Control Parameter
Parameter
Abbr.
Function
Default
Unit
Control Mode Related
Section
DMC Sz Tz
P1-01
●
CTL
Input Setting of Control Mode and
Control Command
0B
pulse
r/min
N-M
O O O
6.1
Table
7.1
P1-02
▲
PSTL Speed and Torque Limit Setting
0
-
O
O
O
Table
7.1
P1-03 AOUT
Polarity Setting of Encoder Pulse
Output
0 -
O
O
O
-
P1-46
▲
GR3
Pulse Number of Encoder Output
2500
pulse
O
O
O
-
P1-55 MSPD
Maximum
Speed
Limit
rated r/min O
O
O -
P1-09 ~
P1-11
SP1~3 Internal Speed Command 1 ~ 3
1000 ~
3000
0.1 r/min
O
6.3.1
P1-12
TQ1
Internal Torque Limit 1
100
%
O
O
-
P1-13 ~
P1-14
TQ2 ~ 3 Internal Torque Limit 2 ~ 3
100
%
O
P1-76 AMSPD
Maximum Rotation Setting of Encoder
Output (OA, OB)
5500 r/min O
O
O -
Torque Control Parameter
Parameter
Abbr.
Function
Default
Unit
Control Mode
Related
Section
DMC Sz Tz
P1-01
●
CTL
Input Setting of Control Mode and
Control Command
0B
pulse
r/min
N-M
O O O
6.1
Table
7.1
P1-02
▲
PSTL Speed and Torque Limit Setting
0
-
O
O
O
Table
7.1
P1-03 AOUT
Polarity Setting of Encoder Pulse
Output
0 -
O
O
O
-
P1-46
▲
GR3
Pulse Number of Encoder Output
2500
pulse
O
O
O
-
P1-55 MSPD
Maximum
Speed
Limit rated
r/min
O
O
O
-
P1-09~
P1-11
SP1~3 Internal Speed Limit 1~3
100 ~
300
r/min
O
O -
P1-12~
P1-14
TQ1~3 Internal Torque Command 1~3
100
%
O
6.4.1
(
★
) Read-only register, can only read the status. For example: P0-00, P0-10 and P4-00, etc.
(
▲
) Setting is invalid when Servo On, e.g. P1-00, P1-46 and P2-33, etc.
(
●
) Not effective until re-power on or off the servo drive, e.g. P1-01 and P3-00.
(
■
) Parameters of no data retained setting, e.g. P2-31 and P3-06.
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...