ASDA-B2-F Communications
September, 2015
8-5
8
11-bit character frame (for 8-bit character)
8N2
Start
bit
7
Stop
bit
0
1
2
3
4
5
6
8-data bits
11-bit character frame
L
H
Stop
bit
8E1
Start
bit
7
Stop
bit
0
1
2
3
4
5
6
8-data bits
11-bit character frame
L
H
Even
parity
8O1
Start
bit
7
Stop
bit
0
1
2
3
4
5
6
8-data bits
11-bit character frame
L
H
Odd
parity
Communication Data Structure
Definitions of data frame for ASCII and RTU mode are as below:
ASCII Mode:
Start Start
character
‟
:” (3AH)
Slave Address
Communication address: 1 byte consists of 2 ASCII codes
Function
Function code: 1 byte consists of 2 ASCII codes
Data (n-1)
Data content: n word = n x 2 byte = consists of n x 4 ASCII codes, n<=10
…….
Data (0)
LRC
Error check: 1 byte consists of 2 ASCII codes
End 1
End code 1: (0DH)(CR)
End 0
End code 0: (0AH)(LF)
The start character of communication in ASCII mode is colon
‟
:” (ASCII code: 3AH). Slave
address is constituted by two characters in ASCII code. The end code is CR (Carriage Return)
and LF (Line Feed). The communication address, function code, data content and error checking
LRC (Longitudinal Redundancy Check), etc. are between the start character and end code.
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...