Communications ASDA-B2-F
8-8
September, 2015
8
RTU Mode:
Command Message (Master):
Response Message (Slave):
Address 01H
Address 01H
Slave Function
06H
Slave Function
06H
Start Data Address
02H (High)
Start Data Address
02H (High)
00H (Low)
00H (Low)
Data Content
00H (High)
Data Content
00H (High)
64H (Low)
64H (Low)
CRC Check Low
89H (Low)
CRC Check Low
89H (Low)
CRC Check High
99H (High)
CRC Check High
99H (High)
Note:
Before and after transmission in RTU mode, 10 ms of silent interval is needed.
Example 3: function code10H,
writing multiple words:
The master issues command to the 1
st
slave and writes 0BB8H and 0000H to the start data
address 0112H. That is to say, 0BB8H is written into 0112H and 0000H is written into 0113H. The
maximum allowable data in one single access is 10. The slave sends the response message to
the master after the writing is completed. The calculation of LRC and CRC will be described in
the following section.
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...