Trial Operation and Tuning ASDA-B2-F
5-4
September, 2015
5
(1) When the screen displays
Warning of overvoltage:
It means the voltage input by the main circuit is higher than the rated range or a power input error
has occurred (incorrect power system).
Corrective action:
Use the voltmeter to measure if the input voltage from the main circuit is within the range of
rated voltage.
Use the voltmeter to measure if the power system complies with the specifications.
(2) When the screen displays
Warning of encoder error:
Check if the motor encoder is securely connected and the wiring is correct.
Corrective action:
Make sure the wiring is the same as the instruction of the user manual.
Check the encoder connector.
Check if the wiring is loose.
Check if the encoder is damaged. If yes, please change a new one.