Chapter 17
17-23
T-17-3
17.2.1.4 COPIER > DISPLAY > CST-STS
0019-9274
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
COPIER > DISPLAY > ANALOG
Item
Level
Description
TEMP
1
Title
Machine temperature (environment sensor)
Purpose
Check the temperature inside the machine.
Note
-
Displays, settings and
adjustment ranges
-
Unit
Deg C
Appropriate guideline
Guaranteed environment for main body: temperature 15 deg C to 27.5 deg C, humidity 25% to 75%
Related service modes
-
Additional description and
notes
Temperature/humidity detected by the environment sensor (left) is not used for the parameter of
control.
HUM
1
Title
Machine humidity (environment sensor)
Purpose
Check the humidity inside the machine.
Note
-
Displays, settings and
adjustment ranges
-
Unit
%RH
Appropriate guideline
Guaranteed environment for main body: temperature 15 deg C to 27.5 deg C, humidity 25% to 75%
Related service modes
-
Additional description and
notes
Temperature/humidity detected by the environment sensor (left) is not used for the parameter of
control.
ABS-HUM
1
Title
Moisture amount (environment sensor)
Purpose
Check the amount of moisture.
Note
-
Displays, settings and
adjustment ranges
XX.xx
Unit
g
Appropriate guideline
0 to 20
Related service modes
-
Additional description and
notes
-
DR-TEMP
1
Title
Display of the temperature around the photosensitive drum
Purpose
To check if a fault in image is attributed to the temperature of the photosensitive drum.
Note
If the temperature is not within the standard range (approx 42.5 deg C), change the switch for heater
temperature setting or check the heater function.
Displays, settings and
adjustment ranges
-
Unit
Deg C
Appropriate guideline
Room temperature -/+ alpha (alpha; rise in temperature inside the machine)
Related service modes
-
Additional description and
notes
-
FIX-C
1
Title
Display of the temperature of the surface of fixing film unit (detected temperature by main thermistor)
Purpose
Check the temperature of the surface of fixing roller (detected temperature by main thermistor)
Note
-
Displays, settings and
adjustment ranges
-
Unit
Deg C
Appropriate guideline
Room temperature to 240 deg C. Approx. 240 deg C during executing a job.
Related service modes
-
Additional description and
notes
-
FIX-E
1
Title
Display of the temperature of the surface of fixing film unit (detected temperature by sub thermistor)
Purpose
Check the temperature of the surface of fixing roller (detected temperature by sub thermistor)
Note
-
Displays, settings and
adjustment ranges
-
Unit
Deg C
Appropriate guideline
Room temperature to 240 deg C. Approx. 240 deg C during executing a job.
Related service modes
-
Additional description and
notes
-
Summary of Contents for iR3245
Page 1: ...Jul 3 2008 Service Manual iR3245 3235 3230 3225 Series...
Page 2: ......
Page 6: ......
Page 25: ...Chapter 1 Introduction...
Page 26: ......
Page 28: ......
Page 64: ......
Page 65: ...Chapter 2 Installation...
Page 66: ......
Page 120: ......
Page 121: ...Chapter 3 Basic Operation...
Page 122: ......
Page 124: ......
Page 128: ......
Page 129: ...Chapter 4 Main Controller...
Page 130: ......
Page 132: ......
Page 134: ...Chapter 4 4 2 F 4 1 1 5 8 9 11 14 12 3 4 10 2 13 7 15 16 17...
Page 152: ......
Page 153: ...Chapter 5 Original Exposure System...
Page 154: ......
Page 184: ......
Page 185: ...Chapter 6 Laser Exposure...
Page 186: ......
Page 188: ......
Page 197: ...Chapter 7 Image Formation...
Page 198: ......
Page 227: ...Chapter 8 Pickup Feeding System...
Page 228: ......
Page 232: ......
Page 244: ...Chapter 8 8 12 For iR3245 3235 3230 F 8 14 1 2 3 4...
Page 261: ...Chapter 8 8 29 10 11 12 13 14 3 1 2 4 5 4 4 1 2 3 5 4 1 2 3 5 5 4 1 2 3 5 4 1 2 3 5...
Page 278: ......
Page 279: ...Chapter 9 Fixing System...
Page 280: ......
Page 282: ......
Page 297: ...Chapter 10 External and Controls...
Page 298: ......
Page 302: ......
Page 315: ...Chapter 10 10 13 2 Uncheck SNMP Status Enabled F 10 11...
Page 342: ......
Page 343: ...Chapter 11 MEAP...
Page 344: ......
Page 346: ......
Page 397: ...Chapter 12 e maintenance imageWARE Remote...
Page 398: ......
Page 400: ......
Page 408: ......
Page 409: ...Chapter 13 Maintenance and Inspection...
Page 410: ......
Page 412: ......
Page 424: ...Chapter 13 13 12...
Page 425: ...Chapter 14 Standards and Adjustments...
Page 426: ......
Page 428: ......
Page 436: ......
Page 437: ...Chapter 15 Correcting Faulty Images...
Page 438: ......
Page 440: ......
Page 465: ...Chapter 16 Self Diagnosis...
Page 466: ......
Page 468: ......
Page 493: ...Chapter 17 Service Mode...
Page 494: ......
Page 498: ......
Page 690: ......
Page 691: ...Chapter 18 Upgrading...
Page 692: ......
Page 694: ......
Page 738: ...Chapter 18 18 44...
Page 739: ...Chapter 19 Service Tools...
Page 740: ......
Page 742: ......
Page 744: ......
Page 745: ...Jul 3 2008...
Page 746: ......