16.1.2 E202 to E248, E280 (Reader)
0019-7880
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
T-16-2
16.1.3 E261 to E315 (DC Controller, Main Controller)
0019-7874
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
T-16-3
Code Cause/Detection
Details
Measures
E202
There is an error in the detection of the CCD home position.
0001 The attempt to detect the home position fails when the CCD is
moved forward.
Disconnect and then connect the harness connector. Replace the optical HP sensor,
optical motor, and reader controller PCB.
0002 The attempt to detect the home position fails when the CCD is
moved back.
Disconnect and then connect the harness connector. Replace the optical HP sensor,
optical motor, and reader controller PCB.
E225
The light intensity of the CCD is faulty.
Disconnect and then connect the flexible cable. Replace the flexible cable, CCD unit,
and reader controller PCB.
E227
The reader unit power supply (24V) is faulty.
0001 At time of power-on, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
0002 At the start of a job, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
0003 At the end of a job, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
0004 When a load is being driven, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
E248
EEPROM error
0001 An error has occurred at power-on.
Replace the reader controller PCB.
0002 An error has occurred during write operation.
Replace the reader controller PCB.
0003 An error has occurred during read operation following write
operation.
Replace the reader controller PCB.
E280
Reading unit communication error
0001 Reception status error
Disconnect and then connect the flexible cable. Replace the flexible cable
0002 Reception interrupt error
Disconnect and then connect the flexible cable. Replace the flexible cable
0003 Insufficient insertion of the reading unit connector
Disconnect and then connect the flexible cable. Replace the flexible cable
Code
Cause
Remedy
E261
The zero-cross signal is faulty.
0000
When the relay is on, the zero-cross signal is not detected for 500 msec
or more.
Replace the AC driver PCB. Replace the DC controller PCB.
E315
There is an error in image data.
0007 There is an error in JBIG encoding.
Turn off and then back on the power.
000d There is an error in JBIG decoding.
Turn off and then back on the power.
000e Error in decoding of software
Replace the main controller PCB
0025 Error in ROTU hardware
Replace SDRAM. Replace HDD. Replace the main controller PCB.
0027 Error in ROTU timeout
Replace SDRAM. Replace HDD. Replace the main controller PCB.
0033 Error in MemFill hardware
Replace the main controller PCB.
0035 Error in MemFill timeout
Replace the main controller PCB.
0100 Error in PrcOverRun
Replace the main controller PCB.
0500 Error in device timeout
[location to be detected] image process module (SCIO)
[Detection timing] when there is no interruption 2 min after the
operation has been started
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0501 Device: abnormal termination error
[location to be detected] image process module (SCIO)
[Detection timing] When abnormal interruption is detected after the
operation has been started.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0510 Device: timeout error
[Location to be detected] image process module (SCIP)
[Detection timing] when there is no interruption 2 min after the
operation has been started.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0511 Device: abnormal termination error
[Location to be detected] image process module (SCIP)
[Detection timing] when abnormal interruption is detected after the
operation has been detected.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0520 Device: timeout error
[Location to be detected] image process module (CMIP)
[Detection timing] When there is no interruption 2 min after the
operation has been started
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0521 Device: abnormal termination error
[Location to be detected] image process module (CMIP)
[Detection timing] when abnormal interruption is detected after the
operation has been detected.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
Summary of Contents for iR3245
Page 1: ...Jul 3 2008 Service Manual iR3245 3235 3230 3225 Series...
Page 2: ......
Page 6: ......
Page 25: ...Chapter 1 Introduction...
Page 26: ......
Page 28: ......
Page 64: ......
Page 65: ...Chapter 2 Installation...
Page 66: ......
Page 120: ......
Page 121: ...Chapter 3 Basic Operation...
Page 122: ......
Page 124: ......
Page 128: ......
Page 129: ...Chapter 4 Main Controller...
Page 130: ......
Page 132: ......
Page 134: ...Chapter 4 4 2 F 4 1 1 5 8 9 11 14 12 3 4 10 2 13 7 15 16 17...
Page 152: ......
Page 153: ...Chapter 5 Original Exposure System...
Page 154: ......
Page 184: ......
Page 185: ...Chapter 6 Laser Exposure...
Page 186: ......
Page 188: ......
Page 197: ...Chapter 7 Image Formation...
Page 198: ......
Page 227: ...Chapter 8 Pickup Feeding System...
Page 228: ......
Page 232: ......
Page 244: ...Chapter 8 8 12 For iR3245 3235 3230 F 8 14 1 2 3 4...
Page 261: ...Chapter 8 8 29 10 11 12 13 14 3 1 2 4 5 4 4 1 2 3 5 4 1 2 3 5 5 4 1 2 3 5 4 1 2 3 5...
Page 278: ......
Page 279: ...Chapter 9 Fixing System...
Page 280: ......
Page 282: ......
Page 297: ...Chapter 10 External and Controls...
Page 298: ......
Page 302: ......
Page 315: ...Chapter 10 10 13 2 Uncheck SNMP Status Enabled F 10 11...
Page 342: ......
Page 343: ...Chapter 11 MEAP...
Page 344: ......
Page 346: ......
Page 397: ...Chapter 12 e maintenance imageWARE Remote...
Page 398: ......
Page 400: ......
Page 408: ......
Page 409: ...Chapter 13 Maintenance and Inspection...
Page 410: ......
Page 412: ......
Page 424: ...Chapter 13 13 12...
Page 425: ...Chapter 14 Standards and Adjustments...
Page 426: ......
Page 428: ......
Page 436: ......
Page 437: ...Chapter 15 Correcting Faulty Images...
Page 438: ......
Page 440: ......
Page 465: ...Chapter 16 Self Diagnosis...
Page 466: ......
Page 468: ......
Page 493: ...Chapter 17 Service Mode...
Page 494: ......
Page 498: ......
Page 690: ......
Page 691: ...Chapter 18 Upgrading...
Page 692: ......
Page 694: ......
Page 738: ...Chapter 18 18 44...
Page 739: ...Chapter 19 Service Tools...
Page 740: ......
Page 742: ......
Page 744: ......
Page 745: ...Jul 3 2008...
Page 746: ......