63.0 Control Panel Events and Reporting Formats
The following table includes each control panel event, the description for each event as it appears in the control panel log, the
reports sent for each event, the zone types linked to the event, and the RPS Event Alert Group number. The RPS Event Group
numbers also correspond with the Personal Dialing Format Event Group numbers. See Personal Dialing Format Configuration
on page 106 for more information.
The last column, Status Reports, indicates System Status events. An “R” indicates that reports for the event follow the System
Status routing. An “S” indicates that the event follows the System Status Swinger Count. System reports do not include an
Area number; they use the account number for Area 1.
If the control panel is configured for network communication, reports are sent using the Contact ID format.
The event numbers shown in the following table are the same numbers that show up on a pager for each corresponding
report.
Event #
Event as shown
in Panel Log
SIA Report
SIA Report Data Contact ID Report Event Description
Zone Types
Linked to Event
RPS Event
Group
Status
Reports
01
AC Fail
AC Trouble
AT
301 AC Loss
AC Power to panel
interrupted.
12
R
S
02
AC Restore
AC Restoral
AR
301 AC Loss
AC Power to panel
restored.
12
R
S
03
Alarm,Tamper
Tamper Alarm ri {area} TA {loop} 137 Tamper
Alarm, Tamper Zone
Type.
4-Tamper 3
04* Alarm,Emergency Emergency
Alarm
ri {area} QA {loop} 101 Personal
Emergency
Alarm, Emergency
Zone Type or ABC
key programmed for
emergency response.
[Q] button.
5- Emergency
Emergency Key
3
05
Alarm,Panic
Panic Alarm
ri {area} PA {loop} 120 Panic
Alarm, Panic-Visible
Zone Type.
6- Visible Panic
Emergency Key
3
06
Alarm,Invisible
Holdup Alarm
ri {area} HA {loop} 120 Panic
Alarm, Panic- Invisible
Zone Type or ABC
key programmed for
panic response.
7-Invisible Panic
Emergency Key
3
07
Alarm,24-hr Burg Burglary Alarm ri {area} BA {loop} 133 24 Hr Safe
Alarm, Burglary Zone
Type.
8- Burglary
15- Door
3
08
Alarm,Cntrl,Dly
Burglary Alarm ri {area} BA {loop} 134 Entry/Exit
Alarm, Delay 1 or
Delay 2 Zone Type.
11- Delay 1
12- Delay 2
3
09 Alarm,Cntrl
Burglary
Alarm ri {area} BA {loop} 130 Burglary
Alarm, Keyswitch or
Follower or Instant
Zone Types.
10- Keyswitch
13- Follower
14- Instant
3
10 Cross,Tamper Burglary
Alarm
Cross Zone
ri {area} BM {loop} 137 Tamper
Alarm, Tamper Zone
Type with Cross Zone
Option selected.
4-Tamper 3
11 Cross,Emergency Burglary Alarm
Cross Zone
ri {area} BM {loop} 101 Personal
Emergency
Alarm, Emergency
Zone Type with Cross
Zone Option selected.
5- Emergency
3
12 Cross,Panic
Burglary
Alarm
Cross Zone
ri {area} BM {loop} 120 Panic
Alarm, Panic-Visible
Zone Type with Cross
Zone Option selected.
6- Visible Panic
3
13 Cross,Invisible Burglary
Alarm
Cross Zone
ri {area} BM {loop} 120 Panic
Alarm, Panic- Invisible
Zone Type with Cross
Zone Option selected.
7-Invisible Panic
3
14
Cross,24hr Burg
Burglary Alarm
Cross Zone
ri {area} BM {loop} 133 24 Hr Safe
Alarm, Burglary Zone
Type with Cross Zone
Option selected
8- Burglary
3
15 Cross,Cntrl,Dly Burglary
Alarm
Cross Zone
ri {area} BM {loop} 134 Entry/Exit
Alarm, Delay 1 or
Delay 2 Zone Type
with Cross Zone
Option selected.
11- Delay 1
12- Delay 2
3
16 Cross,Cntrl
Burglary
Alarm
Cross Zone
ri {area} BM {loop} 130 Burglary
Alarm, Follower, or
Instant Zone Types
with Cross Zone
Option selected.
13- Follower
14- Instant
3
Table 47: Control Panel Events and Reporting Formats
* Help Function Keys report as Zones 100, 101, and 102. The [Q] button on a keyfob reports as User 200.