Page 120 P/N: 4998152533-02
Copyright
2007 Bosch Security Systems, Inc.
DS7200V2-UK Installer's Guide
PART V: REFRENCE MATERIALS
59.5 Miscellaneous
Issues
Problem
Cause
Solution
There are numbers in braces
{###} throughout this
document.
These numbers {###} refer to the event
numbers Control Panel Events and
Reporting
Formats on page 124.
N/A
My printer is printing strange
characters and I cannot read it.
The settings for the DX4010i/DX4010 RS-
232 Serial Interface Module can cause
unexpected printer output.
Verify the settings for the following parameters (see
the DS7200V2 Expert Programming Guide
P/N: 4998153891):
DX4010 Output Configuration (Address 1253)
Baud Rate Configuration (Address 1254)
Parity/Flow Control/Stop Bit Configuration (Address
1255)
Network communication is not
working as expected.
•
The DX4020 Network Interface Module
is not properly wired and/or configured.
•
The
control
panel
is not properly
programmed for network
communication
•
Make sure the DX4020 is properly connected to
the control panel. See DX4020 Wiring on page
30.
•
Make sure the DX4020’s DIP switches are set to
Address 134 (see DX4020 Addressing on page
28).
•
Make sure your selection for Address 3541
includes the “Alternate Communication Interface
at Address 134” option. See Network Interface
Module Options
on page 115.
•
See
the
DX4020 Installation Guide
(P/N: 49522)
for additional configuration requirements.
•
Make sure you are using a valid IP address and
that you entered it correctly. See IP Address 1 (2)
for Destination 1 (2)
on page 112.
•
Make sure selection for Alternate Communication
Options
(see page 113) includes the “Enable
Alternate Communication” option.
60.0 Data Bus Address Quick Reference
Data Bus Address
Device Description
0
Installer Keypad or local connection to RPS
1-8 Keypads/DACMs
1-8
40, 41
DX8010 Telephone Control Module
50
Premises RF Receiver 1
51
Premises RF Receiver 2
52-55
Premises RF Keypads Receiver 1
60-63
Premises RF Keypads Receiver 2
101-107
DX2010 Wired Input Expanders
134
DX4020 Network Interface Module (NIM)
150, 151
DX3010 Output Expanders
250
DX4010i/DX4010 Serial RS-232 Interface Module
Table 44: Data Bus Address Quick Reference