Page 72 P/N: 4998152533-02
Copyright
2007 Bosch Security Systems, Inc.
DS7200V2-UK Installer's Guide
PART IV: CONTROL PANEL PROGRAMMING
41.0 Locations
The DS7240V2 supports up Locations 1 to 40. The DS7220V2 supports Locations 1 to 24.Locations are configured through
the following parameters: Device, Zone Function, Area and Zone Number. All four of these parameters must be configured for
each Location being used in the system.
See Table 27 for location parameter addresses and defaults (defaults are shown like this).
Location Parameters
These columns show the addresses and
defaults programming for each of the four
location parameters. These parameters
configure each location.
Device Parameter Selections
These columns show the selections for the “Device” parameter. The Device parameter tells
the control panel where to find the sensor loop (or transmitter) status for each location.
Location
Device
Zone
Function
Area
Zone #
On-board
(1)
DX2010
1
(2)
DX2010
1
Doubled
(3)
RF Rcvr 1
1,2
(4)
RF Rcvr 2
1,2
(5)
DACM
3
(6)
(optional)
1
0706
(1)
0707
(11)
0708
(1)
0709-0710
(0-1)
On-board
Loop 1
Dbus
1
Adr
101 Loop 1
DBus Adr 50
Xmitter
2
1
DBus Adr 51
Xmitter 1
DACM
2
0711
(1)
0712
(13)
0713
(1)
0714-0715
(0-2)
On-board
Loop 2
DBus Adr
101 Loop 2
DBus Adr 50
Xmitter 2
DBus Adr 51
Xmitter 2
DACM
3
0716
(1)
0717
(14)
0718
(1)
0719-0720
(0-3)
On-board
Loop 3
DBus Adr
101 Loop 3
DBus Adr 50
Xmitter 3
DBus Adr 51
Xmitter 3
DACM
4
0721
(1)
0722
(14)
0723
(1)
0724-0725
(0-4)
On-board
Loop 4
DBus Adr
101 Loop 4
DBus Adr 50
Xmitter 4
DBus Adr 51
Xmitter 4
DACM
5
0726
(1)
0727
(15)
0728
(1)
0729-0730
(0-5)
On-board
Loop 5
DBus Adr
101 Loop 5
DBus Adr 50
Xmitter 5
DBus Adr 51
Xmitter 5
DACM
6
0731
(1)
0732
(15)
0733
(1)
0734-0735
(0-6)
On-board
Loop 6
DBus Adr
101 Loop 6
DBus Adr 50
Xmitter 6
DBus Adr 51
Xmitter 6
DACM
7
0736
(1)
0737
(4)
0738
(1)
0739-0740
(0-7)
On-board
Loop 7
DBus Adr
101 Loop 7
DBus Adr 50
Xmitter 7
DBus Adr 51
Xmitter 7
DACM
8
0741
(1)
0742
(4)
0743
(1)
0744-0745
(0-8)
On-board
Loop 8
DBus Adr
101 Loop 8
DBus Adr 50
Xmitter 8
DBus Adr 51
Xmitter 8
DACM
9
0746
(0)
0747
(14)
0748
(1)
0749-0750
(0-9)
DBus Adr
102 Loop 1
DBus Adr 106
Loop 1; 3.65 k
Ω
DBus Adr 50
Xmitter 9
DBus Adr 51
Xmitter 9
DACM
10
0751
(0)
0752
(14)
0753
(1)
0754-0755
(1-0)
DBus Adr
102 Loop 2
DBus Adr 106
Loop 2; 3.65 k
Ω
DBus Adr 50
Xmitter 10
DBus Adr 51
Xmitter 10
DACM
11
0756
(0)
0757
(14)
0758
(1)
0759-0760
(1-1)
DBus Adr
102 Loop 3
DBus Adr 106
Loop 3; 3.65 k
Ω
DBus Adr 50
Xmitter 11
DBus Adr 51
Xmitter 11
DACM
12
0761
(0)
0762
(14)
0763
(1)
0764-0765
(1-2)
DBus Adr
102 Loop 4
DBus Adr 106
Loop 4; 3.65 k
Ω
DBus Adr 50
Xmitter 12
DBus Adr 51
Xmitter 12
DACM
13
0766
(0)
0767
(14)
0768
(1)
0769-0770
(1-3)
DBus Adr
102 Loop 5
DBus Adr 106
Loop 5; 3.65 k
Ω
DBus Adr 50
Xmitter 13
DBus Adr 51
Xmitter 13
DACM
14
0771
(0)
0772
(14)
0773
(1)
0774-0775
(1-4)
DBus Adr
102 Loop 6
DBus Adr 106
Loop 6; 3.65 k
Ω
DBus Adr 50
Xmitter 14
DBus Adr 51
Xmitter 14
DACM
15
0776
(0)
0777
(14)
0778
(1)
0779-0780
(1-5)
DBus Adr
102 Loop 7
DBus Adr 106
Loop 7; 3.65 k
Ω
DBus Adr 50
Xmitter 15
DBus Adr 51
Xmitter 15
DACM
16
0781
(0)
0782
(14)
0783
(1)
0784-0785
(1-6)
DBus Adr
102 Loop 8
DBus Adr 106
Loop 8; 3.65 k
Ω
DBus Adr 50
Xmitter 16
DBus Adr 51
Xmitter 16
DACM
17
0786
(0)
0787
(14)
0788
(1)
0789-0790
(1-7)
Dbus
1
Adr
103 Loop 1
DBus Adr 106
Loop 1; 2.2 k
Ω
DBus Adr 50
Xmitter
2
17
DBus Adr 51
Xmitter 17
DACM
18
0791
(0)
0792
(14)
0793
(1)
0794-0795
(1-8)
DBus Adr
103 Loop 2
DBus Adr 106
Loop 2; 2.2 k
Ω
DBus Adr 50
Xmitter 18
DBus Adr 51
Xmitter 18
DACM
19
0796
(0)
0797
(14)
0798
(1)
0799-0800
(1-9)
DBus Adr
103 Loop 3
DBus Adr 106
Loop 3; 2.2 k
Ω
DBus Adr 50
Xmitter 19
DBus Adr 51
Xmitter 19
DACM
20
0801
(0)
0802
(14)
0803
(1)
0804-0805
(2-0)
DBus Adr
103 Loop 4
DBus Adr 106
Loop 4; 2.2 k
Ω
DBus Adr 50
Xmitter 20
DBus Adr 51
Xmitter 20
DACM
Table 27: Location Configuration Parameters
1
DBus = Data Bus
2
Xmitter = Transmitter
3
DACM = DACM door contact. Integrating the DACM door contact into the security system is optional. See DACM
Configuration
on page 116 for instructions on integrating the DACM door contact into the security system.