PART I: INTRODUCTION
2.0 Specifications
2.1 Environmental
Specifcations
•
Temperature: 32°F to 122°F (0°C to +50°C)
•
Relative Humidity: 5 to 85% at 86°F (30°C) non-
condensing.
2.2
Voltage Input to Control Panel
•
Primary: 18 VAC, 50 VA max
•
Secondary: Sealed lead acid rechargeable battery
(12 VDC, 7 Ah or 18 Ah).
•
Current Requirements : 100 mA
2.3 Power
Outputs
•
Continuous Power: Up to 1.2 A at 12 VDC nominal
(continuous supply) total for all devices and outputs.
•
Alarm Power: 1.85 A for fire and combined
fire/burglary. Applies to all four outputs combined.
2.4 Minimum
Operating
Voltage
•
10.2 VDC
2.5
Data Bus
•
12 VDC nominal. 305 m of #22 AWG (0.8 mm)
cable.
2.6 Keypads
•
Maximum Number of Keypads per System: 8
•
Compatible Keypads:
−
DS7445i or DS7445V2 LED Keypad,
−
DS7447E or DS7447V2 Text Keypad
−
DS7446KP Keypad
3.0 Standard
Features
3.1 Communicator
The control panel uses a built-in digital communicator
to send reports to the receiver. The panel can send
reports in Contact ID, SIA, SIA 300 with Text, BSIA
Fast Format, Personal Dialing Format, and Basic
Pager Format.
3.2 Zones
The DS7240V2 supports up to 40 zones available
using on-board and off-board (including input
expanders and wireless devices). The DS7240V2
supports up to 5 DX2010 Input Expanders.
The DS7220V2 supports up to 24 zones available
using on-board and off-board (including input
expanders and wireless devices). The DS7220V2
supports up to 3 DX2010 Input Expanders.
On-board sensor loops are marked L-1 to L-8 on both
control panel types.
3.3
Areas and Accounts
The DS7240V2 supports up to 4 independent areas.
The DS7220V2 supports up to 2 independent areas.
All zones can be assigned to a single area, or spread
out over the available areas.
You arm and disarm the panel by area. You can arm
and disarm several areas with one function. You can
also assign a PIN an authority level that allows a user
to arm an area from a remote keypad in another area.
Assigning each area its own account number creates
separate accounts in one panel. Assigning the same
account number to different areas groups them
together into one single account.
Area options include exit tone and delay, separate fire
and burglary outputs and auto opening and closing
skeds (see Skeds on page 95 for more information).
Area 1 can be programmed as a “common” area. See
Arming Options 2 on page 55.
A “First to Open, Last to Close” arming feature is
available. See Arming Options 2 on page 55.
3.4 Programmable
Outputs
Four on-board programmable outputs (PO 1 to PO 4)
are available on both control panels.
The DS7240V2 supports up to 20 programmable
outputs (4 on-board, 16 off-board via 2 DX3010
Output Expanders).
The DS7220V2 supports up to 12 programmable
utputs (4 on-board, 8 off-board via 1 DX3010 Output
Expander).
See On-board Output Setup on page 16, and Off-
board Outputs on page 22 for more information.
3.5 Users
The control panel allows up to 32 individual users.
Each user is assigned a Personal Identification
Number (PIN) and an authority level to determine
which functions can be performed.
3.6 Keyswitch/Exit
Terminator
You can arm and disarm any of the available areas
with maintained or momentary closure devices such
as keyswitches. Zone programming determines loop
responses and which area(s) a keyswitch controls.
Exit Terminator Button function also available.
3.7 Alarm
Event
Memory
The system uses alarm event memory to store alarm
events for each area. You can view the area alarm
events at a keypad assigned to the area. The control
panel clears the area’s alarm event memory and
starts storing new alarm events when you arm the
area.