Page 18 P/N: 4998152533-02
Copyright
2007 Bosch Security Systems, Inc.
DS7200V2-UK Installer's Guide
PART II: SYSTEM INSTALLATION AND SETUP
17.0 RF3227E RF Receiver Setup
For complete instructions regarding the RF3227E
Premises RF Receiver, see its installation instructions
(P/N: 4998122415).
17.1 RF
Receiver
Addressing
Changing the receiver’s address requires that
the power to the receiver (if already applied)
be removed and then reapplied for the
changes to take effect.
Set the RF3227E’s address by placing the address
jumper pin as shown in Figure 15.
No Jumper = Receiver # 1
(Default)
Jumper = Receiver # 2
Address Jumper
Jumper left on pin for storage only.
R
B
G
Y
ADDR
Figure 15: RF3227E Address Jumper Settings
17.2 RF3227E
Installation
Wire the RF3227E to the control panel as shown in
Figure 16. When power is applied to the system, the
red LED at the center of the RF3227E should light.
You can use either one of the Aux Power (-) terminals
and either one of the 12 VDC (+) terminals when
connecting devices to the control panel.
RF3227E
Control Panel
BATT+
BATT-
R
G
B
Y
Red (+)
Black (-)
Green
Yellow
Figure 16: RF3227E to Control Panel Wiring
17.3 RF3227E
Programming
See Premises RF Receiver Options on page 98 for
programming instructions.
17.4 RF
Receiver
Supervision
The control panel supervises communication to the
RF receiver. If it fails to communicate with the RF
receiver, it sends a “Dbus Missing” {125} report.
18.0 Off-board Sensor Loops (DX2010)
18.1 DX2010
(DX2013/DX2014)
Overview
The DS7240V2 supports up to 5 DX2010 Input
Expanders. The DS7220V2 supports up to 3 DX2010
Input Expanders.
Each DX2010 adds eight zones to the system. See
Locations on page 72 for information on how the
DX2010 sensor loops are assigned to zone locations.
•
DX2013 Input Expander: A DX2010 mounted on
an angle bracket for installation inside the CX1011
Enclosure.
•
DX2014 Input Expander: A DX2010 mounted
inside an AE20 ABS plastic enclosure with tamper
switch for installation outside of the CX1011
Enclosure.
•
Current Draw without Aux Output Terminals:
35 mA Standby
•
Current Draw with Aux Output Terminals: 135
mA maximum with connected accessories.
18.2 DX2010
Installation
Failure to follow the mounting instructions in
this document can result in damage to the
module.
The DX2010 contains static-sensitive
components and must be handled with care.
Follow anti-static procedures when handling
this module.
Up to 5 DX2014 modules can be connected to the
DS7240V2. Up to 3 DX2014 modules can be
connected to the DS7220V2. See Figure 21 for wiring
details.
On the DS7240V2, you can install up to 4 DX2013
modules in the CX1011 enclosure. On the DS7220V2,
you can install up to 3 DX2013 modules See Figure
17 for mounting locations.
DX2013 Mounting Locations
DX2013 Mounting Locations
INSTALLER
PO4
PO3
PO2
Figure 17: DX2013 Mounting Locations