RPS Answer Ring Count, Answer Machine Bypass
•
Address: 0213
•
Default: 10 (rings)
•
Selections:
−
0 = Control panel does not answer phone
−
1-13 = Ring Count
−
14 = Answering Machine Bypass 1
−
15 = Answering Machine Bypass 2
The ring count sets the number of rings the control panel waits before picking up and seizing the phone line for a remote
programming session, or for remote arming with a telephone (see Arming Options 1 on page 54).
The control panel does not seize the phone line for remote programming or remote arming with telephone when this parameter
is set to zero (0).
This ring count is used for any control panel arming state, armed or disarmed.
The Answering Machine Bypass function can be restricted to only operate when the system is armed All On or Perimeter Only
(see Arming Options 1 on page 54). When the Answering Machine Bypass function is restricted to only operate when the
system is armed Normal or Perimeter Only, the control panel does not answer the phone for a remote arming session when it
is disarmed (Off). However, [#][4][3] still begins a remote programming session.
Answering Machine Bypass 1
1. Call the premises; let the phone ring no more than two (2) times. Then hang up/disconnect the remote programmer.
2. Wait at least eight (8) seconds to call back, but call back within 45 seconds.
3. The control panel then picks up after the first ring.
Answering Machine Bypass 2
1. Call the premises; let the phone ring no more than four (4) times. Then hang up/disconnect the remote programmer.
2. Wait at least eight (8) seconds to call back, but call back within 45 seconds.