DS7200V2-UK Installer's Guide
Copyright
2007 Bosch Security Systems, Inc.
P/N: 4998152533-02 Page 61
PART IV: CONTROL PANEL PROGRAMMING
Area # Opening {89-96}/Closing {42-67} Reporting Options
•
Address:
−
Area 1: 0296
−
Area 2: 0318
−
Area 3 (DS7240V2 only): 0340
−
Area 4 (DS7240V2 only): 0362
•
Default: 1
•
Selections: 0, 1, 3, 5, 7, 9, 11, 13, 15
Enter This Data Digit to Select Options
Area # Open/Close Reporting Options
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
No Open or Close Reports for Area #
•
Open/Close Reports (for All On) for Area # Enabled
•
•
•
•
•
•
•
•
Restrict Open/Close Reports; Open after Alarm, Close on
Force Arm
•
•
•
•
Open/Close Reports for Perimeter Only (and Partial On)
Mode – Must also select Open/Close Reports (for All On)
•
•
•
•
1 Second Bell Test on Closing Rpt Acknowledgement
•
•
•
•
•
Open/Close Reports for Area # Enabled: If enabled, this option configures Opening/Closing reports for each area. This
also includes the report for the Extend Auto Closing {21} event. Opening {89 to 96} and Closing {42 to 67} reports must be
enabled at the system level. Opening and Closing reports are also enabled by authority level. Reporting must also be
enabled at the system level (see Global Reporting Options on page 47).
•
Restrict Open/Close Reports; Open From Alarm, Close on Force Arm: If this option is enabled, the control panel only
sends opening reports when the user disarms the system after an alarm and when Bell Time has expired. The control panel
only sends closing reports when a zone is force-armed. Force arming is set by authority level and by zone function
configuration.
Enabling the “Restrict Open/Close Reports” option overrides the “First Area to Open/Last Area to
Close Reporting” option. See Arming Options 2 on page 55 for more information on the “Restrict
Open/Close Reports” option.
•
Open/Close Reports for Perimeter Only Mode: If this option is enabled, the control panel sends closing reports when
users arm the system Perimeter Only. If any zones are bypassed, bypass reports are also sent. The control panel sends
opening reports when users disarm the system. Perimeter Only arming is set by authority level and by Zone Function
configuration.
•
1 Second Bell Test on Closing Ack: If this option is enabled, outputs assigned to Alarm Output Functions 1|8, 1|9, 1|10,
and 8|8 activate for one second. See Function, Output ## on page 88 for output function descriptions.