PART IV: CONTROL PANEL PROGRAMMING
Location Parameters
These columns show the addresses and
defaults programming for each of the four
location parameters. These parameters
configure each location. Shaded cells only
apply to the DS7240V2.
Device Parameter Selections
These columns show the selections for the “Device” parameter. The Device parameter tells
the control panel where to find the sensor loop (or transmitter) status for each location.
Location
Device
Zone
Function
Area
Zone #
On-board
(1)
DX2010
1
(2)
DX2010
1
Doubled
(3)
RF Rcvr 1
1,2
(4)
RF Rcvr 2
1,2
(5)
DACM
3
(6)
(optional)
21
0806
(0)
0807
(14)
0808
(1)
0809-0810
(2-1)
DBus Adr
103 Loop 5
DBus Adr 106
Loop 5; 2.2 k
Ω
DBus Adr 50
Xmitter 21
DBus Adr 51
Xmitter 21
DACM
22
0811
(0)
0812
(14)
0813
(1)
0814-0815
(2-2)
DBus Adr
103 Loop 6
DBus Adr 106
Loop 6; 2.2 k
Ω
DBus Adr 50
Xmitter 22
DBus Adr 51
Xmitter 22
DACM
23
0816
(0)
0817
(14)
0818
(1)
0819-0820
(2-3)
DBus Adr
103 Loop 7
DBus Adr 106
Loop 7; 2.2 k
Ω
DBus Adr 50
Xmitter 23
DBus Adr 51
Xmitter 23
DACM
24
0821
(0)
0822
(14)
0823
(1)
0824-0825
(2-4)
DBus Adr
103 Loop 8
DBus Adr 106
Loop 8; 2.2 k
Ω
DBus Adr 50
Xmitter 24
DBus Adr 51
Xmitter 24
DACM
25
0826
(0)
0827
(14)
0828
(1)
0829-0830
(2-5)
DBus Adr
104 Loop 1
DBus Adr 107
Loop 1; 3.65 k
Ω
DBus Adr 50
Xmitter 25
DBus Adr 51
Xmitter 25
DACM
26
0831
(0)
0832
(14)
0833
(1)
0834-0835
(2-6)
DBus Adr
104 Loop 2
DBus Adr 107
Loop 2; 3.65 k
Ω
DBus Adr 50
Xmitter 26
DBus Adr 51
Xmitter 26
DACM
27
0836
(0)
0837
(14)
0838
(1)
0839-0840
(2-7)
DBus Adr
104 Loop 3
DBus Adr 107
Loop 3; 3.65 k
Ω
DBus Adr 50
Xmitter 27
DBus Adr 51
Xmitter 27
DACM
28
0841
(0)
0842
(14)
0843
(1)
0844-0845
(2-8)
DBus Adr
104 Loop 4
DBus Adr 107
Loop 4; 3.65 k
Ω
DBus Adr 50
Xmitter 28
DBus Adr 51
Xmitter 28
DACM
29
0846
(0)
0847
(14)
0848
(1)
0849-0850
(2-9)
DBus Adr
104 Loop 5
DBus Adr 107
Loop 5; 3.65 k
Ω
DBus Adr 50
Xmitter 29
DBus Adr 51
Xmitter 29
DACM
30
0851
(0)
0852
(14)
0853
(1)
0854-0855
(3-0)
DBus Adr
104 Loop 6
DBus Adr 107
Loop 6; 3.65 k
Ω
DBus Adr 50
Xmitter 30
DBus Adr 51
Xmitter 30
DACM
31
0856
(0)
0857
(14)
0858
(1)
0859-0860
(3-1)
DBus Adr
104 Loop 7
DBus Adr 107
Loop 7; 3.65 k
Ω
DBus Adr 50
Xmitter 31
DBus Adr 51
Xmitter 31
DACM
32
0861
(0)
0862
(14)
0863
(1)
0864-0865
(3-2)
DBus Adr
104 Loop 8
DBus Adr 107
Loop 8; 3.65 k
Ω
DBus Adr 50
Xmitter 32
DBus Adr 51
Xmitter 32
DACM
33
0866
(0)
0867
(14)
0868
(1)
0869-0870
(3-3)
DBus Adr
105 Loop 1
DBus Adr 107
Loop 1; 2.2 k
Ω
DBus Adr 50
Xmitter 33
DBus Adr 51
Xmitter 33
DACM
34
0871
(0)
0872
(14)
0873
(1)
0874-0875
(3-4)
DBus Adr
105 Loop 2
DBus Adr 107
Loop 2; 2.2 k
Ω
DBus Adr 50
Xmitter 34
DBus Adr 51
Xmitter 34
DACM
35
0876
(0)
0877
(14)
0878
(1)
0879-0880
(3-5)
DBus Adr
105 Loop 3
DBus Adr 107
Loop 3; 2.2 k
Ω
DBus Adr 50
Xmitter 35
DBus Adr 51
Xmitter 35
DACM
36
0881
(0)
0882
(14)
0883
(1)
0884-0885
(3-6)
DBus Adr
105 Loop 4
DBus Adr 107
Loop 4; 2.2 k
Ω
DBus Adr 50
Xmitter 36
DBus Adr 51
Xmitter 36
DACM
37
0886
(0)
0887
(14)
0888
(1)
0889-0890
(3-7)
DBus Adr
105 Loop 5
DBus Adr 107
Loop 5; 2.2 k
Ω
DBus Adr 50
Xmitter 37
DBus Adr 51
Xmitter 37
DACM
38
0891
(0)
0892
(14)
0893
(1)
0894-0895
(3-8)
DBus Adr
105 Loop 6
DBus Adr 107
Loop 6; 2.2 k
Ω
DBus Adr 50
Xmitter 38
DBus Adr 51
Xmitter 38
DACM
39
0896
(0)
0897
(14)
0898
(1)
0899-0900
(3-9)
DBus Adr
105 Loop 7
DBus Adr 107
Loop 7; 2.2 k
Ω
DBus Adr 50
Xmitter 39
DBus Adr 51
Xmitter 39
DACM
40
0901
(0)
0902
(14)
0903
(1)
0904-0905
(4-0)
DBus Adr
105 Loop 8
DBus Adr 107
Loop 8; 2.2 k
Ω
DBus Adr 50
Xmitter 40
DBus Adr 51
Xmitter 40
DACM
Table 27: Location Configuration Parameters (continued)
1
DBus = Data Bus
2
Xmitter = Transmitter
3
DACM = DACM door contact. Integrating the DACM door contact into the security system is optional. See DACM
Configuration
on page 116 for instructions on integrating the DACM door contact into the security system.