Page 90 P/N: 4998152533-02
Copyright
2007 Bosch Security Systems, Inc.
DS7200V2-UK Installer's Guide
PART IV: CONTROL PANEL PROGRAMMING
Digit
1
Digit
2
Function Type
Description
2 2
‘Panic’ on RF Fob, Bell
Time, PIN resets
Activates when Arm Key (locked icon) and Disarm Key (unlocked icon) on RF Keyfob are pressed at the
same time, or when the [Q] button is pressed and it is set to Duress. Steady and Pulse modes follow bell
time. PIN resets.
2 3
[1]+[3]
keys
2 4
[4]+[6]
keys
2
5
[7]+[9] keys
Activates when appropriate keys are pressed. [System Reset] resets if no alarm response is assigned.
These output types are event-driven. See Mode (Steady, Pulse, One Shot), Output ## on page 92 for
more information.
2 6
3 Unsuccessful Dialing
Attempts.
Activates after 3 unsuccessful dialing attempts. Resets with first successful call or [System Reset].
2 7
Communication Fail
Event. Successful
communication clears.
Activates after Communication Fail Event. Resets with any successful communication or [System Reset].
2
8
Panel Off Hook
Activates when the panel takes the phone line off hook for a dialing attempt. Resets when the control
panel finishes with the phone line and goes on hook.
2
9
Ring Detect
Activates when the control panel detects a ring on the phone line. Resets when ringing stops.
2 10
Voice
Request
For use with an optional Voice Verification Module. The output activates for 2 seconds when the control
panel receives an acknowledgement of an alarm report from a zone with the Voice Verification option
enabled. Mode and Time parameters do not apply.
2
11
Follow Keypad Sounder
Available for on-board outputs only. Output follows keypad sounderMode and Time parameters do not
apply.
2
12
Chime
Activates per Chime Feature configuration. Follows keypad sounder per Chime Tone configuration.
2 13
Ready to Arm (No zones
faulted)
Output is activated (on) when:
(1)
control panel is disarmed & no zones are faulted
(2)
control panel is
armed & no zones are faulted
(3)
control panel is armed & any zone is faulted. Output is deactivated (off)
when panel is disarmed & any zone is faulted. Output is deactivated even if the zone became faulted
when panel was armed.
2 14
Exit
Error/Bad
Set
Activates if zone is faulted at the end of Exit Delay or if a Bad Set condition occurs. Resets when the
system is disarmed.
2
15
Mains 60 Hz
Activates on 60 Hz. Deactivates on 50 Hz.
3 0
Ground
Start
Activates for approximately 0.5 seconds at the start of any dialing attempt. Use to bring up dial tone in
ground start phone systems.
3
1
Follow Zone Function 1
These 15 output functions activate for any fault on any zone assigned to the specified zone function.
To
3
15
Follow Zone Function 15
4 0
Change
Outputs
Activated/deactivated
by Change Outputs function ([#][5][4]).
4
1
Alarm Zone Function 1
These 15 output functions activate for alarms on any zone assigned to the specified zone function and the
area(s) the output is assigned to. They reset when none of the zones assigned to the specified zone
function are in alarm.
To
4
15
Alarm Zone Function 15
5 0
Change
Outputs
Activated/deactivated
by Change Outputs function ([#][5][4]).
5
1
Trouble Zone Function 1
These 15 output functions activate for troubles on any zone assigned to the specified zone function. They
reset when none of the zones assigned to the specified zone function are in trouble.
To
5 15
Trouble Zone Function
15
6 0
Change
Outputs
Activated/deactivated
by Change Outputs function ([#][5][4]).
6
1
Follow PIN 1
These output functions activate when the specified PIN is entered.
Output Function Type 7, 12 follows User 28, which can be programmed as the Guard Code User. See
Guard Code Options on page 71 for more information.
These output types are event-driven. See Mode (Steady, Pulse, One Shot), Output ## on page 92 for
more information.
PIN area assignments are ignored when these output functions are selected.
To
6
15
Follow PIN 15
7
0
Follow PIN 16
To
7
15
Follow PIN 31
Table 32: Output Function Types (continued)