PART IV: CONTROL PANEL PROGRAMMING
Call for Service/System Inactive Options
•
Address: 0231
•
Default: 0
•
Selections: 0-15
Enter This Data Digit to Select Options
Call for Service/System Inactive Options
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
No Options
•
Call for Service Display at Call for Service Interval
•
•
•
•
•
•
•
•
Call for Service Report at Call for Service Interval
•
•
•
•
•
•
•
•
Call for Service Display at System Inactive Interval
•
•
•
•
•
•
•
•
Enable
Weekly
Test
Reminder
•
•
•
•
•
•
•
•
•
Call for Service Display at Call for Service Interval: At the Call for Service Interval, the keypad displays a ‘Call for Service’
trouble at all keypads in all areas and/or sends a report for Area 1. Pressing the [System Reset] key resets the fault in the
area the keypad is assigned to. There is no trouble tone for the Call for Service Interval event.
•
Call for Service Report at Call for Service Interval: The Call for Service {37} Report follows System Status routing. The
interval is in weeks (00 to 99). See Call for Service Interval on page 48.
•
Call for Service Display at System Inactive Interval: At the System Inactive Interval, the keypad displays a ‘Call for
Service’ trouble at all keypads and/or sends a System Inactive {136} report for that area. See System Inactive Interval on
page 48.
•
Enable Weekly Test Reminder: If you select this option, the system keypads display “System Test Due, Press 1 to test.” A
reminder is generated eight (8) days after the last user test. There is no trouble tone for this trouble reminder event. When
the user enters [#][4] to view the trouble, the system displays “System Test Due, Press 1 to test.”
Call for Service Text
•
Address: 1266-1297
•
Default: Blank
•
Selections: See Table 21 on page 40
This parameter provides 16 characters of programmable text to be displayed in the second line of the display whenever the
first line shows “Call for Service.” It is also displayed when the keypad is extinguished and the “Extinguish Mode Displays
Date” option is enabled. See “Keypad Response Options” in the DS7200V2 Expert Programming Guide (P/N: 4998153891) for
information on the Extinguish Mode options.
The following are possible entries for the second line of text:
•
ARC phone number.
•
Preferred phone number called for service.
•
“Press 0 to View”, which shows system trouble details. This tells users which key to press to see system trouble details. See
Call for Service Details
on page 134 for more information.