Page 132 P/N: 4998152533-02
Copyright
2007 Bosch Security Systems, Inc.
DS7200V2-UK Installer's Guide
PART V: REFRENCE MATERIALS
Event
#
Event as shown
in Panel Log
SIA Report
SIA Report Data
Contact ID Report
Event Description
Zone Types
Linked to Event
RPS
Event
Group
Status
Reports
156 User Code Tamper User Code
Tamper
pi {SDI address} JA
{area}
461 Wrong Code
Entry
Invalid User Codes
entered at keypad
exceeded User Tamper
Retry Count. See the
DS7200V2 Expert
Programming Guide
(P/N: 4998153891).
16
R
157 User Level Set
User Level
Set
JZ {changed user}
User Level set.
16
R
158 Walk Test Start
Test Start
ri {area} TS
607 Walk Test Mode Walk Test started with
Walk Test key
sequence ([#][4][4]).
11
159 Walk Test End
Test End
ri {area} TE
607 Walk Test Mode Walk Test ended by
user or timed out.
11
160 Siren Trouble
Bell Fault
YA
320 Sounder Relay Trouble condition
detected on PO 2
configured as
supervised siren output.
12
R
S
161 Siren
Restoral
Bell
Restored
YH
320 Sounder Relay Trouble condition on
supervised siren output
cleared.
12
R
S
162 Grnd
Fault
Equipment
Failure
Condition
IA {0}
310 Ground Fault
Ground fault detected
on panel’s sensor loops,
Option Bus, or Aux
power outputs.
12
R
S
163 Grnd Fault, Rstl
Equipment
Fail Restoral
IR {0}
310 Ground Fault
Ground fault condition
cleared.
12
R
S
164 First
Open
Opening
Report
OP {user}
400 Open/Close
Panel is configured for
multiple area first to
open, last to close
functions. See
Open/Close Reporting
Options on page 56.
First area has opened.
10
165 Last
Close
Closing
Report
CL {user}
400 Open/Close
Panel is configured for
multiple area first to
open, last to close
functions. See
Open/Close Reporting
Options on page 56.
Last area has closed.
10
166 AltCom
Cond
Network
Condition
ss {condition} NC
{path}
350 Communication
Trouble
Trouble detected on
Alternate
Communication
network.
12
R
S
167 AltComm
Fail
Network
Failure
ss {condition} NT
{path}
350 Communication
Trouble
Network failure detected
on Alternate
Communication
network.
12
R
S
168 AltComm
Rstrl
Network
Restoral
ss {condition} NR
{path}
350 Communication
Trouble
Network communication
resumed on alternate
communications
network.
12
R
S
169 Reserved
170 Reserved
171 Reserved
172 Reserved
173 Rstrl,
Swinger
Burglary
Unbypass
ri {area} BU {loop}
575 Swinger Shunt Restoral from Swinger
Shunt.
Any zone type
8
174 Rstrl,Fire,Miss
Local
Event
Only
Local Event Only
Restoral from Fire
Missing. Local event, no
report.
1- Fire
2- Fire with
Alarm
Verification
7
Table 47: Control Panel Events and Reporting Formats (continued)