DS7200V2-UK Installer's Guide
Copyright
2007 Bosch Security Systems, Inc.
P/N: 4998152533-02 Page 127
PART V: REFERENCE MATERIALS
Event #
Event as shown
in Panel Log
SIA Report
SIA Report Data
Contact ID
Report
Event Description
Zone Types
Linked to
Event
RPS
Event
Group
Status
Reports
57 Frc,All,+Dly,RPS Forced
Closing ri
{area}
CF {254}
400 O/C
System forced All On with
Entry/Exit Delay by RPS.
58 Frc,All,+Dly,Tel Forced
Closing ri
{area} CF {253}
400 O/C
System forced All On with
Entry/Exit Delay by
Telephone.
10
59
Frc,All,+Dly,Usr
Forced Closing
ri {area} CF {user}
401 O/C by User System forced All On with
Entry/Exit Delay by User.
10
60 Frc,All,-Dly,RPS Forced
Closing ri
{area}
CF {254}
400 O/C
System forced All On with
no delay (instant) by RPS.
61
Frc,All,-Dly,Usr
Forced Closing
ri {area} CF {user}
401 O/C by User System forced All On with
no delay (instant) by User.
10
62 Frc,Prt,+Dly,Tmr Forced
Perimeter
Arm
ai {252} NF {area}
456 Partial Arm System forced Perimeter
Only with Entry/Exit Delay
by Sked (Timer).
10
63 Frc,Prt,+Dly,KS Forced
Perimeter
Arm
ss {255} NF {area}
456 Partial Arm System forced Perimeter
Only with Entry/Exit Delay
by Keyswitch.
10
64 Frc,Prt,+Dly,
RPS
Forced Perimeter
Arm
ri {area} NF {254}
456 Partial Arm System forced Perimeter
Only with Entry/Exit Delay
by RPS.
65 Frc,Prt,+Dly,Usr Forced
Perimeter
Arm
ri {area} NF {254}
456 Partial Arm System forced Perimeter
Only with Entry/Exit Delay
by User.
10
66 Frc,Prt,-Dly,
RPS
Forced Perimeter
Arm
ri {area} NF {254}
456 Partial Arm System forced Perimeter
Only with no delay (instant)
by RPS.
67 Frc,Prt,-Dly,Usr Forced
Perimeter
Arm
ri {area} NF {254}
456 Partial Arm System forced Perimeter
Only with no delay (instant)
by User.
10
68 Reserved
69 Comm
Fail
Communications
Fail
rg {destination} YC
354 Failure to
communicate
event
Report failed to reach
routing destination.
12
R
S
70 CommFail,
AltComm
Communications
Fail
pi {SDI Address} YC 354 Failure to
communicate
event
Report failed to reach
routing destination
configured for Alternate
Communication.
12
R
S
71 Comm
Restoral Communications
Restoral
rg {destination} YK
354 Failure to
communicate
event
After communication fail,
report sent successfully to
routing destination.
12
R
S
72 CommRstl,
AltComm
Communications
Restoral
pi {SDI Address} YK 354 Failure to
communicate
event
After communication fail,
report sent successfully to
routing destination
configured for Alternate
Communication.
12
R
S
73 Date/Time
Change Time Changed
JT {user}
625 Time/Date
reset
Date/Time in panel
changed.
12
R
74*
Duress
Hold Up Alarm
ri {area} HA {loop}
121 Duress
User entered Duress PIN or
pressed Panic key
sequence or [Q] button** on
RF Keyfob. The Duress
report is sent in addition to
any other report that the
user’s action would
generate.
1
75
Fire,Alarm
Fire Alarm
ri {area} FA {loop}
110 Fire
Alarm event on fire zone
type.
1- Fire
2- Fire with
Alarm
Verification
2
Table 47: Control Panel Events and Reporting Formats (continued)
* This event reports a user 200 when sent using SIA and Contact ID reporting formats.
** See “[Q] Button Alarm Response Options” in the DS7200V2 Expert Programming Guide (P/N: 4998153891).