DS7200V2-UK Installer's Guide
Copyright
2007 Bosch Security Systems, Inc.
P/N: 4998152533-02 Page 87
PART IV: CONTROL PANEL PROGRAMMING
Area, Output #
•
Address: See Table 31
•
Default:
−
Outputs 1-4, 11-20: 1 (Assign Output to Area 1)
−
Outputs 5-10: 0 (No Area Assigned – Output disabled)
•
Selections: 0-15
Enter This Data Digit to Select Options
Output Area Options
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
No Area Assigned (Output disabled)
•
Assign Output to Area 1
•
•
•
•
•
•
•
•
Assign Output to Area 2
•
•
•
•
•
•
•
•
Assign Output to Area 3 (DS7240V2 only)
•
•
•
•
•
•
•
•
Assign Output to Area 4 (DS7240V2 only)
•
•
•
•
•
•
•
•
This parameter assigns an area to the output. Functions are only activated by keypads or zones assigned to the same area.
Outputs can be assigned to multiple areas.