Page 80 P/N: 4998152533-02
Copyright
2007 Bosch Security Systems, Inc.
DS7200V2-UK Installer's Guide
PART IV: CONTROL PANEL PROGRAMMING
42.0 Zone Function Configuration
The control panel can monitor any combination of up to 40 sensor loops and/or RF transmitters. Each sensor loop or
transmitter is assigned to a location. Each location is assigned to one of 15 zone functions so that the control panel knows how
to respond to sensor loop or transmitter changes.
See Table 30 for zone function configuration parameter addresses and defaults (defaults are shown like this).
Zone
Function
Zone Function Type
Pulse
Count
Pulse
Count
Time
Options 1
Options 2
Report
Enable
Trouble
Response
Alarm
Route
Restoral
Route
1
Adr 0906
(1: 24-hr Fire)
Adr 0907
(0)
Adr 0908
(0)
Adr 0909
(0)
Adr 0910
(2)
Adr 0911
(9)
Adr 0912
(1)
Adr 0913
(1)
2
Adr 0914
(2: 24-hr Fire with Verify)
Adr 0915
(0)
Adr 0916
(0)
Adr 0917
(0)
Adr 0918
(2)
Adr 0919
(9)
Adr 0920
(1)
Adr 0921
(1)
3
Adr 0922
(3: 24-hr Control Input)
Adr 0923
(0)
Adr 0924
(0)
Adr 0925
(11)
Adr 0926
(0)
Adr 0927
(2)
Adr 0928
(1)
Adr 0929
(1)
4
Adr 0930
(4: 24-hr Tamper)
Adr 0931
(0)
Adr 0932
(0)
Adr 0933
(8)
Adr 0934
(3)
Adr 0935
(9)
Adr 0936
(1)
Adr 0937
(1)
5
Adr 0938
(5: 24-hr Emergency)
Adr 0939
(0)
Adr 0940
(0)
Adr 0941
(1)
Adr 0942
(3)
Adr 0943
(9)
Adr 0944
(1)
Adr 0945
(1)
6
Adr 0946
(6: 24-hr Visible Panic)
Adr 0947
(0)
Adr 0948
(0)
Adr 0949
(1)
Adr 0950
(3)
Adr 0951
(9)
Adr 0952
(1)
Adr 0953
(1)
7
Adr 0954
(7: 24-hr Invisible Panic)
Adr 0955
(0)
Adr 0956
(0)
Adr 0957
(1)
Adr 0958
(3)
Adr 0959
(9)
Adr 0960
(1)
Adr 0961
(1)
8
Adr 0962
(8: 24-hr Burglary)
Adr 0963
(0)
Adr 0964
(0)
Adr 0965
(1)
Adr 0966
(3)
Adr 0967
(13)
Adr 0968
(1)
Adr 0969
(1)
9
Adr 0970
(13: Controlled Follower)
Adr 0971
(0)
Adr 0972
(0)
Adr 0973
(5)
Adr 0974
(7)
Adr 0975
(9)
Adr 0976
(1)
Adr 0977
(1)
10
Adr 0978
(10: Controlled Keyswitch)
Adr 0979
(0)
Adr 0980
(0)
Adr 0981
(8)
Adr 0982
(0)
Adr 0983
(2)
Adr 0984
(1)
Adr 0985
(1)
11
Adr 0986
(11: Entry/Exit Dly 1)
Adr 0987
(0)
Adr 0988
(0)
Adr 0989
(5)
Adr 0990
(7)
Adr 0991
(9)
Adr 0992
(1)
Adr 0993
(1)
12
Adr 0994
(12: Entry/Exit Dly 2)
Adr 0995
(0)
Adr 0996
(0)
Adr 0997
(5)
Adr 0998
(7)
Adr 0999
(9)
Adr 1000
(1)
Adr 1001
(1)
13
Adr 1002
(13: Controlled Follower)
Adr 1003
(0)
Adr 1004
(0)
Adr 1005
(1)
Adr 1006
(7)
Adr 1007
(9)
Adr 1008
(1)
Adr 1009
(1)
14
Adr 1010
(14: Controlled Instant)
Adr 1011
(0)
Adr 1012
(0)
Adr 1013
(1)
Adr 1014
(7)
Adr 1015
(9)
Adr 1016
(1)
Adr 1017
(1)
15
Adr 1018
(14: Controlled Instant -
Perimeter)
Adr 1019
(0)
Adr 1020
(0)
Adr 1021
(5)
Adr 1022
(7)
Adr 1023
(9)
Adr 1024
(1)
Adr 1025
(1)
Table 30: Zone Function Configuration
See the DS7200V2 Expert Programming Guide (P/N: 4998153891) for complete instructions on zone function configuration.