Page 24 P/N: 4998152533-02
Copyright
2007 Bosch Security Systems, Inc.
DS7200V2-UK Installer's Guide
PART II: SYSTEM INSTALLATION AND SETUP
3. Secure the DX3013 to the CX1011 enclosure
wall with a mounting screw (provided with
DX3013). See Figure 32.
Enclosure Back Wall
Mounting Screw
Front of
Angle Bracket
Front of
DX3013
Figure 32: Mounting the DX3013 (Step 3)
Distance from the control panel is determined by the
total combined wire length of all devices (including
keypads) connected to the control panel’s Data Bus
terminals. The combined wire length must not exceed
305 m using #22 AWG (0.8 mm) wire.
19.5 DX3010
Wiring
Refer to Table 9 for Data Bus wire length
requirements.
If the DX3010 is to be installed far from the
control panel, the control panel cannot be
used to power the DX3010. An external power
supply must be used. See Figure 34 for
external power supply connections.
Power
Source
#22 AWG
(0.8 mm)
#18 AWG
(1.2 mm)
Control Panel
to DX3010
Control
Panel
12.2 m
24.4 m
Control Panel
to DX3010
305 m
610 m
External
Power Supply
to DX3010
External
Power
Supply
12.2 m
24.4 m
Table 9: DX3010 Wire Lengths
You can use either one of the Aux Power (-) terminals
and either one of the 12 VDC (+) terminals when
connecting devices to the control panel.
BATT+
BATT-
NC
NO
C
8
Y
B
R
G
Control Panel
DX3010
Red (+)
Black (-)
Green
Yellow
Red (+)
Black (-)
Green
Yellow
Output Activated State
NC
NO
C
Output De-activated State
NC
NO
C
Figure 33: DX3010 to Control Panel Wiring
If you need to power the DX3010 from an external
power supply, connect it to the power supply and the
control panel.
BATT+
BATT-
NC
NO
C
8
Y
B
R
G
Control Panel
DX3010
Red (+)
Black (-)
Green
Yellow
Black (-)
Green
Yellow
12 VDC
External Power Supply
(+)
(-)
Figure 34: DX3010 to External Power Supply Wiring
Do not tie the black (-) output to earth
ground when using any external power
supply. A ground fault condition is reported