DS7200V2-UK Installer's Guide
Copyright
2007 Bosch Security Systems, Inc.
P/N: 4998152533-02 Page 55
PART IV: CONTROL PANEL PROGRAMMING
Arming Options 2
•
Address: 0259
•
Default: 0
•
Selections: 0-15
Enter This Data Digit to Select Options
Arming Options 2
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
No Options Enabled
•
First Area to Open/Last Area to Close Reporting
•
•
•
•
•
•
•
•
Make Area 1 Common Area
•
•
•
•
•
•
•
•
Enable All Areas All On ([#][8][0])
•
•
•
•
•
•
•
•
Enable All Areas All Off ([#][8][1])
•
•
•
•
•
•
•
•
•
First Area to Open {164}/Last Area to Close {165} Reporting: If this option is enabled, the system sends one Closing
{165} report when all areas are turned On and one Opening {164} report when any area is turned Off. Opening/Closing
reports must be enabled for all areas.
Enabling the “Restrict Open/Close Reports” option overrides the “First Area to Open/Last Area to
Close Reporting” option. See Area # Opening {89-96}/Closing {42-67} Reporting Options on page 61
for more information on the “Restrict Open/Close Reports” option.
All area account numbers must be the same in order to send Area 1’s account numbers. See Areas
on page 60 for account number programming instructions.
•
Make Area 1 Common Area: If this option is enabled, all other areas are made common to Area 1. Area 1 arms when all
the other areas are armed All On, and Area 1 disarms when any other area is disarmed.
•
Enable All Areas All On Function ([#][8][0]): If this option is enabled, all areas arm when a user enters [#][8][0]. Faulted
zones are force-armed. Enable all areas in which the user has the appropriate authority level.
•
Enable All Areas Off Function ([#][8][1])*: If this option is enabled, all areas disarm when a user enters [#][8][1]. This
function always requires a PIN. Enable all areas in which the user has the appropriate authority level.