DS7200V2-UK Installer's Guide
Copyright
2007 Bosch Security Systems, Inc.
P/N: 4998152533-02 Page 37
PART II: SYSTEM INSTALLATION AND SETUP
27.9
Keypad Test ([#][9][1])
The keypad test function is only available to keypads
on Data Bus Addresses 1 to 8. This test does not
apply to an Installer Keypad. This test is only
available to an installer.
When the keypad test begins, the keypad’s volume
and display brightness (text keypad only) are set to
full on. When the test ends, the volume and
brightness return to the previously saved settings.
Follow these steps to perform a keypad test from an
text keypad:
Press [#][9][1].
Enter the Installer PIN if prompted.
Press each key on the keypad when prompted. Each
key press serves as a sounder test and display
test.
Observe the keypad’s LED’s when prompted. This
prompt occurs following a 3-second delay after all
keys are pressed and all LEDs turn on.
Press [#] to end the test. The keypad returns to the
idle condition (normal display).
Follow these steps to perform a keypad test from an
LED keypad:
1. Press
[#][9][1].
2. Enter the Installer PIN if prompted. All the LEDs
flash (including Status and Zone LEDs).
3. Press each keypad key. As keys are pressed, a
corresponding LED stays on solid.
4. Press [#] to end the test when all keys are
pressed and the remaining Status LEDs turn on
solid. The keypad returns to the idle condition
(normal display).