UART/RS232 Triggering and Serial Decode
•
A parity error will cause the associated data word to be shown in red,
which includes the 5- 8 data bits and the optional 9th bit.
UART/RS232 Totalizer
The UART/RS232 totalizer consists of counters that provide a direct
measure of bus quality and efficiency. The totalizer appears on screen
whenever UART/RS232 Decode is ON in the Serial Decode Menu.
The totalizer is running, counting frames and calculating the percentage of
error frames, even when the oscilloscope is stopped (not acquiring data).
The ERR (error) counter is a count of Rx and Tx frames with parity
errors. The TX FRAMES and RX FRAMES counts include both normal
frames and frames with parity errors. When an overflow condition occurs,
the counter displays
OVERFLOW
.
The counters can be reset to zero by pressing the
Reset UART Counters
softkey in the UART/RS232 Settings Menu.
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...