If don't care (0xXX) is selected for data, the data will be ignored.
The trigger will always occur on the 17th clock for 7- bit addressing
or 26th clock for 10- bit addressing.
c
If you have selected a three- byte trigger, press the
Data2
value softkey
and turn the Entry knob to select the 8- bit data pattern on which to
trigger.
I2C Serial Decode
To set up the oscilloscope to capture I2C signals, see
"Setup for I2C
Signals"
on page 361.
To set up I2C serial decode:
1
Press
[Serial]
to display the Serial Decode Menu.
2
Choose 7- bit or 8- bit address size. Use 8- bit address size to include the
R/W bit as part of the address value, or choose 7- bit address size to
exclude the R/W bit from the address value.
3
If the decode line does not appear on the display, press the
[Serial]
key
to turn it on.
4
If the oscilloscope is stopped, press the
[Run/Stop]
key to acquire and
decode data.
N O T E
To display I2C serial decode, see
"I2C Serial Decode"
on page 366.
N O T E
For I2C triggering setup see
"I2C Triggering"
on page 362.
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...