![Agilent Technologies InfiniiVision 3000 3024A MSO-X User Manual Download Page 398](http://html1.mh-extra.com/html/agilent-technologies/infiniivision-3000-3024a-mso-x/infiniivision-3000-3024a-mso-x_user-manual_2868679398.webp)
398
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
26
MIL-STD-1553/ARINC 429 Triggering and Serial Decode
For more information on using the
[Navigate]
key and controls, see
"Navigating the Time Base"
on page 58.
Setup for ARINC 429 Signals
Setup consists of first connecting the oscilloscope to a ARINC 429 signal
using a differential active probe (the Agilent N2791A is recommended),
then using the Signals Menu to specify the signal source, the high and low
trigger threshold voltage levels, the signal speed, and the signal type.
To set up the oscilloscope to capture ARINC 429 signals:
1
Press
[Label]
to turn on labels.
2
Press
[Serial]
.
3
Press the
Serial
softkey, turn the Entry knob to select the desired slot
(Serial 1 or Serial 2), and press the softkey again to enable decode.
4
Press the
Mode
softkey; then, select
ARINC 429
decode mode.
5
Press the
Signals
softkey to open the ARINC 429 Signals Menu.
6
Press
Source
; then, select the channel for the ARINC 429 signal.
The label for the ARINC 429 source channel is automatically set.
7
Press the
Speed
softkey and specify the speed of the ARINC 429 signal:
•
High
— 100 kb/s.
•
Low
— 12.5 kb/s.
8
Press the
Signal Type
softkey and specify the signal type of the ARINC
429 signal:
•
Line A (non-inverted)
.
•
Line B (inverted)
.
•
Differential (A-B)
.
9
Press the
Auto Setup
softkey to automatically set these options for
decoding and triggering on ARINC 429 signals:
•
High Trigger Threshold: 3.0 V.
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...