16
Waveform Generator
Pressing a signal parameter softkey can open a menu for selecting the
type of adjustment. For example, you can choose to enter amplitude
and offset values, or you can choose to enter high- level and low- level
values. Or, you can choose to enter frequency values or period values.
Keep pressing the softkey to select the type of adjustment. Turn the
Entry knob to adjust the value.
Notice that you can select between coarse and fine adjustments for
frequency, period, and width. Also, pushing the Entry knob is a quick
way to toggle between coarse and fine adjustments.
The
Settings
softkey opens the Waveform Generator Settings Menu which
lets you make other settings related to the waveform generator.
See:
•
"To output the waveform generator sync pulse"
on page 259
•
"To specify the expected output load"
on page 259
•
"To use waveform generator logic presets"
on page 260
•
"To add noise to the waveform generator output"
on page 261
•
"To restore waveform generator defaults"
on page 261
Cardiac
Use the Frequency/Frequency
Fine/Period/Period Fine, Amplitude, and Offset
softkeys to set the cardiac signal parameters.
100 mHz to
200 kHz
20 mVpp to
5 Vpp
±1.25 V
Gaussian
Pulse
Use the Frequency/Frequency
Fine/Period/Period Fine, Amplitude, and Offset
softkeys to set the gaussian pulse signal
parameters.
100 mHz to
5 MHz
20 mVpp to
4 Vpp
±1.25 V
1
When the output load is 50
Ω
, these values are halved.
Waveform
Type
Characteristics
Frequency
Range
Max.
Amplitude
(High-Z)
1
Offset
(High-Z)
1
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...