Getting Started
1
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
35
4.
Entry knob
The Entry knob is used to select items from menus and to change values.
The function of the Entry knob changes based upon the current menu
and softkey selections.
Note that the curved arrow symbol
above the entry knob
illuminates whenever the entry knob can be used to select a value. Also,
note that when the Entry knob
symbol appears on a softkey, you
can use the Entry knob, to select values.
Often, rotating the Entry knob is enough to make a selection. Sometimes,
you can push the Entry knob to enable or disable a selection. Pushing the
Entry knob also makes popup menus disappear.
5.
Tools keys
The Tools keys consist of:
• [Utility] key — Press this key to access the Utility Menu, which lets
you configure the oscilloscope's I/O settings, use the file explorer, set
preferences, access the service menu, and choose other options. See
Chapter 19
, “Utility Settings,” starting on page 283.
• [Quick Action] key — Press this key to perform the selected quick
action: measure all snapshot, print, save, recall, freeze display. and
more. See
“Configuring the [Quick Action] Key"
on page 298.
• [Analyze] key — Press this key to access analysis features like
trigger level setting, measurement threshold setting, Video trigger
automatic set up and display, mask testing (see
Chapter 15
, “Mask
Testing,” starting on page 239), or the DSOX3PWR power
measurement and analysis application.
• [Wave Gen] key — Press this key to access waveform generator
functions. See
Chapter 16
, “Waveform Generator,” starting on page
251.
6.
Trigger controls
These controls determine how the oscilloscope triggers to capture data.
See
Chapter 10
, “Triggers,” starting on page 141 and
Chapter 11
, “Trigger
Mode/Coupling,” starting on page 177.
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...