![Agilent Technologies InfiniiVision 3000 3024A MSO-X User Manual Download Page 270](http://html1.mh-extra.com/html/agilent-technologies/infiniivision-3000-3024a-mso-x/infiniivision-3000-3024a-mso-x_user-manual_2868679270.webp)
270
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
17
Save/Recall (Setups, Screens, Data)
•
Whether acquisitions are running. When stopped, data comes from the
raw acquisition record. When running, data comes from the smaller
measurement record.
•
Whether the oscilloscope was stopped using
[Stop]
or
[Single]
. Running
acquisitions split memory to provide fast waveform update rates. Single
acquisitions use full memory.
•
Whether only one channel of a pair is turned on. (Channels 1 and 2 are
one pair, channels 3 and 4 are the other.) Acquisition memory is
divided among the channels in a pair.
•
Whether reference waveforms are on. Displayed reference waveforms
consume acquisition memory.
•
Whether digital channels are on. Displayed digital channels consume
acquisition memory.
•
Whether segmented memory is on. Acquisition memory is divided by
the number of segments.
•
The horizontal time/div (sweep speed) setting. At faster settings, fewer
data points appear on the display.
•
When saving to a CSV format file, the maximum number of data points
is 64K.
When necessary, the Length control performs a "1 of n" decimation of the
data . For example: if the
Length
is set to 1000, and you are displaying a
record that is 5000 data points in length, four of each five data points will
be decimated, creating an output file 1000 data points in length.
When saving waveform data, the save times depend on the chosen format:
See Also
•
"Binary Data (.bin) Format"
on page 325
•
"CSV and ASCII XY files"
on page 332
•
"Minimum and Maximum Values in CSV Files"
on page 333
Data File Format
Save Times
BIN, ALB
fastest
ASCII XY
medium
CSV
slowest
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...