206
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
13
Cursors
•
Press the
Cursors
softkey; then, turn the Entry knob.
The
X1 X2 linked
and
Y1 Y2 linked
selections let you adjust both cursors at
the same time, while the delta value remains the same. This can be
useful, for example, for checking pulse width variations in a pulse train.
The currently selected cursor(s) display brighter than the other cursors.
6
To change the cursor units, press the
Units
softkey.
In the Cursor Units Menu:
You can press the
X Units
softkey to select:
•
Seconds (s)
.
•
Hz (1/s)
.
•
Phase (°)
— when selected, use the
Use X Cursors
softkey to set the
current X1 location as 0 degrees and the current X2 location as 360
degrees.
•
Ratio (%)
— when selected, use the
Use X Cursors
softkey to set the
current X1 location as 0% and the current X2 location as 100%.
You can press the
Y Units
softkey to select:
•
Base
— the same units used for the source waveform.
•
Ratio (%)
— when selected, use the Use
Y Cursors
softkey to set the
current Y1 location as 0% and the current Y2 location as 100%.
For phase or ratio units, once the 0 and 360 degree or 0 and 100%
locations are set, adjusting cursors will display measurements relative
to the set locations.
7
Adjust the selected cursor(s) by turning the Cursors knob.
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...