Oscilloscope Bandwidth Required
The oscilloscope bandwidth required to accurately measure a signal is
primarily determined by the signal's rise time, not the signal's frequency.
You can use these steps to calculate the oscilloscope bandwidth required:
1
Determine the fastest edge speeds.
You can usually obtain rise time information from published
specifications for devices used in your designs.
2
Compute the maximum "practical" frequency component.
From Dr. Howard W. Johnson's book,
High- Speed Digital Design – A
Handbook of Black Magic
, all fast edges have an infinite spectrum of
frequency components. However, there is an inflection (or "knee") in the
frequency spectrum of fast edges where frequency components higher
than f
knee
are insignificant in determining the shape of the signal.
f
knee
= 0.5 / signal rise time (based on 10% - 90% thresholds)
f
knee
= 0.4 / signal rise time (based on 20% - 80% thresholds)
3
Use a multiplication factor for the required accuracy to determine the
oscilloscope bandwidth required.
See Also
Choosing an Oscilloscope with the Right Bandwidth for your
Application
, Agilent Application Note 1588
(
"http://cp.literature.agilent.com/litweb/pdf/5989- 5733EN.pdf"
)
Required accuracy
Oscilloscope bandwidth required
20%
f
BW
= 1.0 x f
knee
10%
f
BW
= 1.3 x f
knee
3%
f
BW
= 1.9 x f
knee
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...