![Agilent Technologies InfiniiVision 3000 3024A MSO-X User Manual Download Page 236](http://html1.mh-extra.com/html/agilent-technologies/infiniivision-3000-3024a-mso-x/infiniivision-3000-3024a-mso-x_user-manual_2868679236.webp)
236
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
14
Measurements
6
Press the
Upper
softkey; then, turn the Entry knob to set the upper
measurement threshold value.
Decreasing the upper value below the set middle value will
automatically decrease the middle value to be less than the upper value.
The default upper threshold is 90% or 1.50 V.
•
If threshold
Type
is set to
%
, the upper threshold value can be set
from 7% to 95%.
Measurement Window with Zoom Display
When the zoomed time base is displayed, you can choose whether
measurements are made in the Main window portion of the display or the
Zoom window portion of the display.
1
Press the
[Meas]
key.
2
In the Measurement Menu, press the
Settings
softkey.
3
In the Measurement Settings Menu, press the
Meas Window
softkey; then,
turn the Entry knob to select from:
•
Auto Select
— The measurement is attempted in the lower, Zoom
window; if it cannot be made there, the upper, Main window is used.
•
Main
— The measurement window is the upper, Main window.
•
Zoom
— The measurement window is the lower, Zoom window.
Measurement Statistics
Press the
[Meas]
key to enter the Measurement Menu. By default, statistics
are displayed, and frequency and voltage are measured on channel 1.
Select the measurements you desire for the channels you are using (see
"Measurements Summary"
on page 215).
From the Measurement Menu, press the
Statistics
softkey to enter the
Statistics Menu.
Summary of Contents for InfiniiVision 3000 3024A MSO-X
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Page 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Page 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Page 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Page 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Page 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Page 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Page 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Page 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...