Note
Action
xx1800003100
Valid for CRB 1100-4/0.58
Separate the extender unit and wrist from the
housing.
4
Disconnecting the axis-3 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800003003
Remove the lower arm support cover.
2
xx1800003004
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
3
Continues on next page
Product manual - CRB 1100
407
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued