Loosening the cable package from axis-4 gearbox
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800003031
Valid for CRB 1100-4/0.475
Access the cable package locking screw on the
axis-4 gearbox from the wrist and then loosen the
locking screw.
2
xx1800003000
Valid for CRB 1100-4/0.58
Remove the plug screw and washer on the ex-
tender unit to access the cable package locking
screw on the axis-4 gearbox and then loosen the
locking screw.
3
xx1800003001
Continues on next page
Product manual - CRB 1100
445
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the extender unit and wrist
Continued