Note
Action
J5.C2 connector assembly tool, in-
cluded in the special toolkit
3HAC071022-001
For robots with Ethernet cabling
Reconnect the connector J5.C2 using the tool.
4
xx1800002948
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
5
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Refit the cover.
6
Tightening torque: 1.2 Nm
xx2000002219
Reconnecting the air hoses, CP/CS cabling and Ethernet cabling (if equipped)
Note
Action
xx1800002500
Reconnect the air hoses in a cross pattern to the
Y-shaped connectors.
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same Y-shaped connector.
1
Continues on next page
Product manual - CRB 1100
227
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the upper cable package
Continued