Securing the upper cable package to the axis-4 gearbox
Note
Action
Holes to be aligned are shown in
the following figure.
Make sure that:
•
The hole on the cable protection tube is
aligned with the locking screw hole on the
gearbox.
•
The cable protection tube surface is com-
pletely parallel with the pulley cover at one
side and with the flange at the other side.
1
xx1800003018
Surfaces to be paralleled are
shown in the following figures.
xx1800003019
xx1800003020
Continues on next page
Product manual - CRB 1100
425
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......