6.2 Synchronization marks and axis movement directions
6.2.1 Synchronization marks and synchronization position for axes
Introduction
This section shows the position of the synchronization marks and the
synchronization position for each axis.
Synchronization marks, CRB 1100
1
2
5
6
4
3
xx1800002455
CAUTION
To calibrate the axis 6, the notch on the wrist must be aligned with the marked
pin hole on the tool flange. Before installing a tool on the tool flange, make sure
a visible mark has been made to the tool at the corresponding position.
Product manual - CRB 1100
657
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
6 Calibration
6.2.1 Synchronization marks and synchronization position for axes
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......