Configuring the PLC
The safety PLC connecting to the laser scanner and controller must support
PROFIsafe and can act as a master. Before configuration, make sure the PLC is
loaded with the GSD files of the controller and laser scanner.
Detailed procedures about how to add an external device to the PLC and how to
configure detailed settings, see the user manual from the vendor. Following lists
the necessary settings during PLC configuration:
•
Add the scanner to the PLC by adding a
mS3 6Byte In/Out PROFIsafe V2.6.1
module.
The parameters f_dest_address and f_source_address are set to 12 and 1,
respectively.
•
Add the controller to the PLC by adding the
DI 8 bytes
,
DO 8 bytes
,
SDI 8
bytes
and
SDO 8 bytes
modules.
The parameters f_dest_address and f_source_address for the SDI are set to
3 and 2, respectively, and for the SDO are set to 5 and 4, respectively.
•
Make sure the address for the SDO signal is the first address of
SDO 8 bytes
slot.
•
Create variables.
Example address
i
Type
Name
%I3.0
Bool
ProtectingTrigger
%I4.1
Bool
WarningTrigger
%I3.2
Bool
ProtectingSSTTrigger
%I3.3
Bool
WarningTSPTrigger
%Q68.0
Bool
ProtectingArea
%Q68.1
Bool
WarningArea
%Q68.2
Bool
ProtectingAreaSST
%Q68.3
Bool
WarningAreaTSP
%Q68.4
Bool
SafetyCommunicationEnable
%Q3.0
Bool
ActivateScanner
i
%I3.
X
and %I4.
X
are the addresses of the laser scanner; %Q68.
X
is the address of the
OmniCore controller.
%Q3.0 is for activating the monitoring cases of the laser scanner.
•
Check the communication between the PLC and controller is well and activate
the laser scanner; set up the communication between the laser scanner, PLC
and OmniCore controller.
Configuring SafeMove
With RobotStudio
Basic steps for configuring SafeMove are as follows:
1 Make some initial preparations.
2 Configure system parameters.
3 Set the input and output size and name of the PROFINET internal device.
Continues on next page
Product manual - CRB 1100
123
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.5.1 Configuration of one PROFINET-base laser scanner (RobotWare 7.5 or earlier)
Continued
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......