Note
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Screw: M2.5x6 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the cable bracket.
3
Tightening torque: 0.6 Nm
xx1800003006
Screw: M3x12 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate.
4
Tightening torque: 0.4 Nm
xx1800003004
Continues on next page
Product manual - CRB 1100
385
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued