3.7.5.7 Configuration of two SafetyIO-base laser scanners (RobotWare 7.6 or later)
Preparing the robot system
Required options for system setup
When setting up the system using
Installation Manager
in RobotStudio, select the
options
[3043-3] SafeMove Collaborative
and
[3051-4] Dual IO Package
, and the
correct robot variant. The option
Drive System IRB Small Robot
is selected
automatically after the robot type is determined.
Supported parameters for connections to scanners and scalable I/O device
The laser scanners use a PC-based software tool to configure the connection
parameters that are used to connect to the OmniCore system. The supported
parameters of the OmniCore system are predefined in the configuration file which
could be loaded to the system after the Collaborative Speed Control add-in is
installed, see
Information about Collaborative Speed Control add-in on page 96
The I/O configuration can be seen using I/O Engineering Tool in RobotStudio.
The following table lists the device mapping information of Scalable_IO signals,
which are automatically configured after the add-in installation.
Device
Device mapping
Signal name
ABB_Scalable_IO
0
ABB_Scalable_IO_0_DI1
i
ABB_Scalable_IO
1
ABB_Scalable_IO_0_DI2
ABB_Scalable_IO
2
ABB_Scalable_IO_0_DI3
ii
ABB_Scalable_IO
3
ABB_Scalable_IO_0_DI4
ABB_Scalable_IO
4
ABB_Scalable_IO_0_DI5
ABB_Scalable_IO
5
ABB_Scalable_IO_0_DI6
ABB_Scalable_IO
6
ABB_Scalable_IO_0_DI7
ABB_Scalable_IO
7
ABB_Scalable_IO_0_DI8
i
Value of ProtectingArea depends on logic AND value of ABB_Scalable_IO_0_DI1,
ABB_Scalable_IO_0_DI2, ABB_Scalable_IO_0_DI5 and ABB_Scalable_IO_0_DI6. For definition of
ProtectingArea, see
Configuring the laser scanner on page 147
ii
Value of WarningArea depends on logic AND value of ABB_Scalable_IO_0_DI3,
ABB_Scalable_IO_0_DI4, ABB_Scalable_IO_0_DI7 and ABB_Scalable_IO_0_DI8. For definition of
WarningArea, see
Configuring the laser scanner on page 147
.
Continues on next page
146
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.5.7 Configuration of two SafetyIO-base laser scanners (RobotWare 7.6 or later)
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......