ii
If the lead-through device is installed, the C2 connector will be used for the lead-through device
and 6 wires are occupied.
Connector kits (optional)
Connector kits, wrist
The table describes the CP/CS and Ethernet (if any) connector kits for wrist.
Art. no.
Description
Position
3HAC066098-001
M12 CPCS Male straight connect-
or kits
CP/CS
Connector kits
3HAC066099-001
M12 CPCS Male angled connector
kits
3HAC067413-001
M12 Ethernet Cat5e Male straight
connector kits
Ethernet
3HAC067414-001
M12 Ethernet Cat5e Male angled
connector kits
Protection covers
Protection covers for water and dust proofing
Protection covers are delivered together with the robot and must be well fitted to
the connectors in any application requiring water and dust proofing.
Always remember to refit the protection covers after removing them.
(A)
(C)
(C)
(B)
xx1900000132
CP/CS or Ethernet connector protection covers
A
SMB connector protection cover
B
Air hose connector protection covers
C
92
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.2 Customer connections
Continued
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......