Refitting the upper cable package
Use these procedures to refit the upper cable package.
Refitting the upper cable harness through the axis-4 gearbox
Note
Action
Cable protection tube orientation:
use the notch (A) on the cable pro-
tection tube as a reference when
inserting the cable package, which
should be at the opposite direction
to the locking screw hole (B) on the
gearbox.
Insert the cable package in the housing and
through the axis-4 gearbox.
Tip
Wrap the connectors with the masking tape.
1
xx1800003017
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
xx1800003601
Continues on next page