Note
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Insert the cabling and connectors into the wrist.
3
Reconnecting the axis-6 motor connectors
Note
Action
xx1800002994
Reconnect the connectors.
•
FB6
•
MP6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
1
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Insert the cabling and connectors into the wrist.
3
Refitting the lamp unit
Notice that the procedure is valid only when the lamp unit needs a replacement.
Note
Action
Multi-color lamp unit (14 mm):
3HAC076495-001
Refit the lamp unit.
1
xx2000002221
Continues on next page
Product manual - CRB 1100
225
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the upper cable package
Continued