Note
Action
xx1800002946
Carefully pull out lamp unit connector behind the
air hose connectors and disconnect the connector
J5.UL.
4
xx2100000293
For robots with CP/CS cabling
Disconnect the connector.
•
J5.C1
5
J5.C2 connector assembly tool: -
For robots with Ethernet cabling
6
xx1800002948
Disconnect the connector J5.C2 using the tool.
Removing the wrist covers
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
Product manual - CRB 1100
397
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued