Reconnecting the connectors at the division point
Note
Action
xx1800003029
Insert the female header of the connectors to the
connector plate.
1
xx1800003030
Reconnect the connectors.
•
J2.FB2,3,4,5,6
•
J2.MP3,4,5/6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate.
4
Tightening torque: 0.8 Nm
xx1800002489
Continues on next page
316
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued