Note
Action
xx1800003000
Valid for CRB 1100-4/0.58
Remove the plug screw and washer on the ex-
tender unit to access the cable package locking
screw on the axis-4 gearbox and then loosen the
locking screw.
3
xx1800003001
Disconnecting the axis-4 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800003011
Remove the housing cover.
2
Continues on next page