Note
Action
xx2100000293
For robots with CP/CS cabling
Reconnect the connector.
•
J5.C1
3
J5.C2 connector assembly tool, in-
cluded in the special toolkit
3HAC071022-001
For robots with Ethernet cabling
Reconnect the connector J5.C2 using the tool.
4
xx1800002948
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
5
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Refit the cover.
6
Tightening torque: 1.2 Nm
xx2000002219
Refitting the covers
Note
Action
Apply grease to the cable package, cover all
moving area of the package.
1
Apply grease to the covers that have contacting
area with the cable package.
2
Continues on next page
Product manual - CRB 1100
433
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued